| 如何在 Windows 2000 的驱动程序(SYS)中得到当前进程的进程名和完整路径? |
| 编号:2002050701 |
| 正文: |
| 首先利用PsGetCurrentProcess或IoGetCurrentProcess函数得到当前进程的句柄,这个句柄是指向_EPROCESS结构的指针,_EPROCESS的结构如下: typedef struct _EPROCESS { KPROCESS Pcb; NTSTATUS ExitStatus; KEVENT LockEvent; DWORD LockCount; QWORD CreateTime; QWORD ExitTime; PVOID LockOwner; DWORD UniqueProcessId; QWORD ActiveProcessLinks; DWORD QuotaPeakPoolUsage [2]; // NP, P DWORD QuotaPoolUsage [2]; // NP, P DWORD PagefileUsage; DWORD CommitCharge; DWORD PeakPagefileUsage; DWORD PeakVirtualSize; QWORD VirtualSize; DWORD Vm [12]; DWORD LastProtoPteFault; DWORD DebugPort; DWORD ExceptionPort; DWORD ObjectTable; DWORD Token; DWORD WorkingSetLock [8]; DWORD WorkingSetPage; BOOLEAN ProcessOutswapEnabled; BOOLEAN ProcessOutswapped; BOOLEAN AddressSpaceInitialized; BOOLEAN AddressSpaceDeleted; DWORD AddressCreationLock [9]; DWORD ForkInProgress; DWORD VmOperation; DWORD VmOperationEvent; DWORD PageDirectoryPte; QWORD LastFaultCount; PVOID VadRoot; DWORD VadHint; DWORD CloneRoot; DWORD NumberOfPrivatePages; DWORD NumberOfLockedPages; WORD w184; BOOLEAN ExitProcessCalled; BOOLEAN CreateProcessReported; HANDLE SectionHandle; struct _PEB *Peb; // offset 0x1B0 PVOID SectionBaseAddress; PVOID QuotaBlock; NTSTATUS LastThreadExitStatus; PROCESS_WS_WATCH_INFORMATION WorkingSetWatch; DWORD InheritedFromUniqueProcessId; ACCESS_MASK GrantedAccess; DWORD DefaultHardErrorProcessing; DWORD LdtInformation; DWORD VadFreeHint; DWORD VdmObjects; KMUTANT ProcessMutant; BYTE ImageFileName [16]; // offset 0x1FC DWORD VmTrimFaultValue [2]; PVOID Win32Process; DWORD d1F8; DWORD d1FC; } EPROCESS, * PEPROCESS, **PPEPROCESS; 从上面这个结构可以看出,进程名称就是ImageFileName,只要用_EPROCESS的基地址加上偏移地址0x1FC就可以得到进程名称的地址,代码如下: char *ProcessName = (char*)PsGetCurrentProcess() + 0x1FC; KdPrint((“Current Process Name: %s\n”, ProcessName)); 要得到完整路径还需要利用_EPROCESS结构中的_PEB结构指针来得到ProcessParameters的地址。ProcessParameters保存着进程的完整路径。可以通过DDK附带的WinDbg工具打开一个可执行程序,然后用!peb命令来显示_PEB的结构信息。如下所示: ——————————————————————————————————————— > !peb Debugger extension library [F:\WINNT\system32\ntsdexts] loaded PEB at 7FFDF000 InheritedAddressSpace: No ReadImageFileExecOptions: No BeingDebugged: Yes ImageBaseAddress: 00400000 Ldr.Initialized: Yes Ldr.InInitializationOrderModuleList: 131f88 . 132998 Ldr.InLoadOrderModuleList: 131ee0 . 132988 Ldr.InMemoryOrderModuleList: 131ee8 . 132990 00400000 D:\NtSysInfo.exe 77F80000 F:\WINNT\System32\ntdll.dll 77E60000 F:\WINNT\system32\KERNEL32.dll 77DF0000 F:\WINNT\system32\USER32.dll 77F40000 F:\WINNT\system32\GDI32.DLL 76AF0000 F:\WINNT\system32\comdlg32.dll 70BD0000 F:\WINNT\system32\SHLWAPI.DLL 77D90000 F:\WINNT\system32\ADVAPI32.dll 77D20000 F:\WINNT\system32\RPCRT4.DLL 71700000 F:\WINNT\system32\COMCTL32.DLL 77560000 F:\WINNT\system32\SHELL32.DLL 78000000 F:\WINNT\system32\MSVCRT.DLL 777C0000 F:\WINNT\System32\WINSPOOL.DRV SubSystemData: 0 ProcessHeap: 130000 ProcessParameters: 20000 WindowTitle: 'D:\NtSysInfo.exe' ImageFile: 'D:\NtSysInfo.exe' CommandLine: '"D:\NtSysInfo.exe" ' DllPath: 'D:\;.;F:\WINNT\System32;F:\WINNT\system;F:\WINNT;F:\WINNT\system32;F:\WINNT;F:\WINNT\System32\Wbem;J:\WINDOWS;J:\WINDOWS\COMMAND;E:\WINDOWS\SYSTEM\WBEM;J:\WINDOWS;J:\WINDOWS\COMMAND;E:\WINDOWS\SYSTEM\WBEM;J:\WINDOWS;J:\WINDOWS\ COMMAND' Environment: 0x10000 从WinDbg输出的PEB结构信息可以看出ProcessParameters的地址为0x20000,ImageFile字段就是进程的完整路径。那么PorcessParamters的地址又保存在_PEB结构的什么地方呢?_PEB结构的基地址为0x7ffdf000,通过WinDbg的“db 0x7ffdf000” 命令显示0x7ffdf000地址的信息可以发现ProcessParameters的地址保存在_PEB结构的0x10偏移量处,内容为0x20000。 继续用“db 0x20000”命令显示ProcessParameters地址的内容,偏移量为0x3C处保存完整路径的地址,0x3C处的内容如果是:0x20670,利用“db 0x20670”即可显示出完整路径。完整路径用UNICODE格式保存。 我们利用程序模拟上面的步骤则可以得到当前进程的完整路径,代码如下: PCWSTR GetCurrentProcessFileName() { DWORD dwAddress = (DWORD)PsGetCurrentProcess(); if(dwAddress == 0 || dwAddress == 0xFFFFFFFF) return NULL; dwAddress += 0x1B0; if((dwAddress = *(DWORD*)dwAddress) == 0) return 0; dwAddress += 0x10; if((dwAddress = *(DWORD*)dwAddress) == 0) return 0; dwAddress += 0x3C; if((dwAddress = *(DWORD*)dwAddress) == 0) return 0; KdPrint((“Current Process Full Path Name: %ws\n”, (PCWSTR)dwAddress)); return (PCWSTR)dwAddress; } Windows NT与Windows 2000的_EPROCESS结构略有不同,所以偏移地址也不相同,故此上面的程序不能正常运行于Windows NT。要想在Windows NT下获得进程名和完整路径可以用类似的方法得出正确的偏移地址,进而编写出正确的程序。 如果想得到关于如何在Windows 9x的驱动程序(VXD)中得到当前进程的进程名和完整路径或者其他更多知识,可以访问费尔安全实验室的网站:http://www.filseclab.com。 关于如何在Windows 9x的驱动程序(VXD)中得到当前进程的进程名和完整路径请参阅 费尔个人防火墙知识库:2002050702。 |
| 版权所有 © 费尔安全实验室 2002 保留所有权利 |